X
close

AMERIWATER LABORATORY SERVICES

AAMI Contaminant Testing

AmeriWater offers reliable ANSI/AAMI/ISO 23500 and ANSI/AAMI ST108 testing for tap and product water contaminants in dialysis centers and central sterile processing applications. AAMI Contaminant Testing is to validate the final water quality meets the current AAMI standards for contaminant levels in dialysis and central sterile markets that have an impact on patient safety and processing of surgical instruments. We deliver results in 5 business days, with a 3-day STAT option available for an extra fee.

Microbiological Testing

Testing for bacteria is crucial to help prevent serious risk to dialysis patients with weakened immune systems from kidney disease. In addition, high bacteria levels in water can contaminate medical devices and lead to post-surgery infections. Our Microbiological Testing utilizes Heterotrophic Plate Count Methods to ensure the most accurate CFU/ml results. Testing results provided 24 – 48 hours from receipt of sample.

Total Organic Carbon (TOC) Testing

TOC Testing is critical, as high TOC levels can serve as nutrition to microorganisms and contribute to microbial growth on medical devices. They can also interfere with detergents or disinfectants effectiveness for cleaning. Testing result turnaround times will vary.

Endotoxin Testing

AmeriWater utilizes the Kinetic Chromogenic Testing Method for endotoxin, providing exact endotoxin levels with both positive and negative controls to ensure accurate results. The test is performed to ensure endotoxin levels are within current AAMI 23500 and ST108 standards. A high concentration of endotoxins present in water can cause pyrogenic reactions in dialysis or surgical patients. Testing results provided 24 – 48 hours from receipt of sample.

Reverse Osmosis Feed Water Analysis

The Reverse Osmosis Feed Water Analysis offers comprehensive insights into the chemistry of your feed water, covering minerals, organics, and contaminants. This detailed analysis helps to determine the type of pretreatment equipment required to effectively operate your reverse osmosis system and enhance the final water quality. Testing results provided 2 weeks from receipt of sample. Note: This test does not include Silt Density Index testing. If you require this, contact us directly for assistance.

Particle Size Distribution Analysis

This is a technique for analyzing the suspended solids within a water sample. Our Particle Size Distribution Analysis provides valuable insights into the range and quantities of these particles, which can significantly impact water quality and treatment processes. Testing results provided 2 days from receipt of sample.

As long-established water purification specialists, AmeriWater has a deep understanding of the critical role high-purity water plays in many industries.

Our Laboratory Services offer a full range of water testing capabilities to provide your facility with the knowledge and clarity to ensure patient and equipment safety.

Free Consultation

As water purification specialists, AmeriWater also offers FREE consultation by phone regarding disinfection procedures, monitoring schedules, proper design layout and more to help solve your water treatment issues.

Free Testing Kit

AmeriWater provides a complimentary kit containing all necessary supplies for drawing and shipping water samples to simplify the testing process for you.

Why should you test your Water Quality?

Facilities in a wide variety of markets need water treatment for dialysis, central sterile services, laboratories, and industrial applications.

By validating the performance of your water treatment system and routinely monitoring the water quality, you can identify and address potential water concerns before they cause harm to patients, processes and devices.

Validating and routinely monitoring water quality is important to:

Ensure that the water is safe for patients.
Contaminants in water can cause serious infections or toxicity to patients. Contaminants can also have an adverse effect on surgical instruments that are reprocessed.
Protect the effectiveness of cleaning and sterilization processes.
For example, hard water can interfere with the effectiveness of cleaning solutions, while high levels of minerals can interfere with steam sterilization.
Prevent damage to medical devices.
Water impurities can damage medical devices, especially those with delicate components. For example, corrosion can occur on metal devices if exposed to water with high levels of minerals.
Dig deep into water chemistry.
Analysis reveals minerals, organics and hidden contaminants that can cause potential seasonal and overall performance issues, disrupting your facility’s operations.
Comply with AAMI requirements.
Analysis reveals minerals, organics and hidden contaminants that can cause potential seasonal and overall performance issues, disrupting your facility’s operations.

What Else Do You Need to Know About Ameriwater Lab Services?

Download Our
Brochure!