Dual Alternating Commercial Water Softeners – 40 up to 124 GPM
The dual alternating regeneration water softener design rovides a 24/7 supply of soft water. The Fleck 3900 NXT brass valve, with 3″ water meter and electronic control provides quick setup and programming. The composite resin tanks, polyethylene brine tank and high capacity polystyrene resin make a long lasting system.
Features
Specifications
Features
- Electronic programmable control enables complete flexibility of the duration of the regeneration cycles, usage limits, and provides access to the history of usage and regenerations. 12V operation makes for easy installation. Program and history are maintained in non-volatile memory.
- Highest capacity softening resin is utilized for durability and efficiency.
- Resin tank is poly glass composite with 125 PSIG operation and 300 PSIG test pressure.
- Brine tank is of rigid polyethylene with brine well, automatic air eliminator safety valve, brine line, and cover sized to match the softener.
Specifications
Operating Requirements
Pressure: 25-125 PSI
Temperature: 35-100°F
Electrical: 120V, 60 Hz, 5 amps
Turbidity: 5 NTU max.
Chlorine: 1 ppm max.
Iron: 2 ppm max.
Model | 0096085 | 0096086 | 0096087 | 0096088 | 0096089 |
Max. Capacity Gr.* | 300,000 | 450,000 | 600,000 | 900,000 | 1,050,000 |
Min. Capacity Gr.* | 200,000 | 300,000 | 400,000 | 600,000 | 700,000 |
Cont. Flow GPM** | 40 | 93 | 102 | 118 | 124 |
Peak Flow GPM** | 52 | 120 | 132 | 153 | 161 |
Drain Flow GPM | 15 | 25 | 35 | 50 | 65 |
Resin Tank Size In. | 24 x 72 | 30 x 72 | 36 x 72 | 42 x 72 | 48 x 72 |
Brine Tank Size In. | 30 x 50 | 39 x 50 | 50 x 60 | 50 x 60 | 50 x 60 |
Resin Qty. Cu. Ft. | 10 | 15 | 20 | 30 | 40 |
Brine Tank Fill Lbs. | 1,200 | 2,200 | 4,100 | 4,100 | 4,100 |
Valve Pipe Size In. | 3 | 3 | 3 | 3 | 3 |
Space W x D x H In. | 80 x 30 x 91 | 103 x 39 x 97 | 126 x 50 x 99 | 138 x 50 x 104 | 150 x 50 x 107 |
Shipping Weight Lbs. | 2,100 | 3,100 | 4,000 | 6,200 | 8,200 |
* Capacity: Maximum @ 15 lbs. salt/cu. ft., Minimum @ 7 lbs. salt/cu. ft. ** Continuous Flow @ 15 lbs. drop. Peak Flow @ 25 lbs. PSI drop. |